Finish the whole project.

The final rack is only part of the job. Plan the equipment, shutdown dependencies, access windows, data processing, and building handback together.

Acceptance, handling, and terms confirmed before scheduling.

Data center decommissioning — illustrative material or equipment photography
Illustrative photography · not an Ironbay facility
Define the scope

What belongs in the conversation.

Describe what you have. Flag what needs a closer look.

01

Servers, storage & network equipment

02

Racks, cabinets & cable infrastructure

03

UPS systems and batteries for separate review

04

Server rooms, cages & multi-rack projects

A considered process

The right next step.
Not an assumption.

Rack and room retirements, equipment removal, media decisions, and handback planning.

Use the planning guide ↗
01

Define what leaves—and what stays

Map the room, rack positions, device identifiers, and exclusions. Make the difference between a rack removal, a cage closure, and a full room handback explicit. Agree on the acceptance criteria with facilities before setting the removal sequence.

02

Put shutdown authority with the right people

Your authorized IT and facilities owners must approve migration, retention, system shutdown, and release. Electrical isolation and specialist disconnection work belong to qualified personnel. A removal request is not authorization to disconnect live infrastructure.

03

Plan the route out of the building

Share loading-dock restrictions, freight-elevator details, working hours, escorts, and insurance requirements. Identify unusually heavy or fixed items. Confirm packing, lifting, labor, and transport responsibilities in the scope.

04

Track two kinds of closeout

Physical handback and data/reporting closeout are separate milestones. Reconcile removed assets, processing results, exceptions, material destinations, and any resale settlement rather than treating an empty room as proof that every task is finished.

Before the first conversation

A useful brief.
A clearer quote.

Rough quantities are welcome. You do not need to solve every detail before asking.

  • Rack or room count and inventory
  • Shutdown owner and handback deadline
  • Media policy and processing location
  • Building access and removal constraints
Start this request
Certifications & compliance

ISO 14001:2015, R2v3 & e-Stewards certified. Confirm the applicable scope and records for your project.

Review the standards & documentation ↗
Good questions

Before you get started.

Can a project include metal and batteries?
Include those streams in the brief, but keep them identified separately. Battery condition, electrical work, lifting, and processing requirements need their own review.
Do you provide a project checklist?
Yes. The resource center has an ungated, branded data center decommissioning checklist with planning questions and space for owners and evidence.